Pinpoint Laser Systems
Call 1-800-757-5383  

Laser Measuring

Laser Measuring

What is the distance from the transmitted laser beam to the base of the Laser?

The laser beam from the Laser Microgage 2D exits at a point 1 inch up from the base and 1 inch in from each side. The Laser Microgage 2000 transmits a laser beam is centered 1.0 inch above the base of the laser and 0.625 inch in from each side edge.

What is the angular tolerance for the receiver?

The laser can enter the receiver + 12 degrees off centerline with minimal influence on measuring accuracy. We recommend for consistency that users try to keep the laser square to the front of the receiver if possible. A helpful trick is to align the receiver until the faint laser beam reflections, off the front of the receiver, falls back onto the front of the laser.

Laser Options

What lasers are available for the Laser Microgage line?

There are several standard lasers available for the Laser Microgage line and a variety of custom configurations. The most standard Laser Microgage has a rectangular housing with flat machined reference surfaces and variety of threaded mounting points for use on fixtures, tripods, and machinery. This configuration is available for the Laser Microgage 2D and 2000 lines. A round cylindrical laser is also available for bore alignment, spindle alignment, checking lathes and other mechanical alignment applications. In addition to these standard models, Pinpoint also provides lasers in customized housings for specific customer applications.

How can the Laser be attached to my machine?

Microgage lasers are equipped with threaded mounting holes (10-32 and ¼-20) on five of their six mounting surfaces.  Pinpoint also provides tripod mounts, clamp mounts, magnet mounts and a variety of laser adjustment fixtures to accommodate customer mounting needs.

Range

What is the range of the Laser Microgage?

The Laser Microgage measures lateral displacement across the laser beam path in one direction with the Laser Microgage 2000 or in 2 directions with the Laser Microgage 2D. The typical range of displacement for a Laser Microgage 2000 receiver is 1 inch in a single direction and 0.75 inch in two directions for the Laser Microgage 2D. Pinpoint does have other receivers that measure up to 3 inches and in multiple directions.

How far away can the receiver be from the laser?

The Laser Microgage 2D system will operate when the distance between the receiver and the laser is a few inches out to about 180 feet (55 meters). The Laser Microgage 2000 can go out to 100 feet (30 meters).

Measuring Distance

Can the Laser Microgage measure distance between the laser and receiver?

Not at this time, but stay tuned. Currently, the Laser Microgage measures very precisely across the laser beam in the X and Y axes.


Industry Aligned

Talk to a Pinpoint
Engineer

After filling out this inquiry form, you can immediately download Pinpoint product and application information.


Pinpoint Laser Systems featured in May 2011 Issue of Photonics Spectra

Photonics Spectra


Our Customers

Our Customers Say

"We actually used it (Cylindrical Laser) for aligning the Power Rollers the turbine rotor sits on during inspections and testing. It went extremely well. Didn’t suffer the delays we encountered last year when the turbine rotor shouldered up on the power roller (cost us about 20 hours). It has already paid for itself. Thanks for your help."

Edward W. Williams
TG/MSR Project Manager
Brunswick Nuclear Plant,
Progress Energy Carolinas

"We purchased the Microgage 2000 and the Lateral Pitch Plate for measuring flatness, parallelism, and other applications. We have been extremely satisfied with the entire process. The quality of the parts we received is of the highest order and the accuracy of the measurements is truly spectacular."

Dr. Joshua R. Williams,
Sr. Scientist
XStream Systems, Inc

"This is just an update for you and a testimony to the great help that your product was in assisting us during our installation and maintenance work and shutdown periods. We installed the wedge blocks with ease and they performed in the very same manner. Great product!"

Jeffery W. Evans
Westinghouse Electric Co, LLC

"We are having great success with this unit (Microgage 2D Universal Kit) in moving my machines this year."

Martin Usher
Apollo Machine

"The sales department was very knowledgeable and the technical department was very thorough. The Microgage 2000 was exactly what we needed. We are extremely happy with the results."

Dr. Joshua R. Williams
Senior Scientist
XStream Systems, Inc.

"One thing that stands out and has been commented on by all who have seen the equipment is its design and build quality. It is a beautifully engineered and built piece of equipment, which is a pleasure to use. Well Done!"

Nenad Sarcevic, Engineer
Airbus UK

"We purchased the Microgage 2000 Universal Kit to align a test apparatus so that the floor of the test tank and the left wall are straight down their respective lengths of 80 feet to 0.0002 inch or better. The floor and left wall also had to be perpendicular to each other

The laser system worked extremely well, proving us and our customer the confidence that the installation when as planned within the tolerances."

Drew Disney
Project Coordinator/Quality Assurance Manager
Hewitt (Brockville) Ltd

"We have been using your equipment regularly to align our scanners for last 4 years with excellent results! After using these we actually wonder how we could align our scanners with out using this tool! These have indeed helped us to improve our sensors measurement accuracy many fold."

Manish Garg
Jasch Industries Ltd.

"We have been very pleased with its (Microgage 2D) performance, as well as Ken Nelson’s advice and help. It is quite likely we will be purchasing other units in the future."

Walt Corey
President
Pickwick Manufacturing Services

“I used the Laser for 6 weeks at the factory in China. It is an awesome tool. I aligned everything on the machine and managed to get the whole machine straight, level and square. I had several fixtures made the worked well for quick setup. My only regret is that I couldn't get them to purchase the upgraded controller. Thanks for everything. You have a quality product that delivers exactly as advertised.”

Todd Fletcher
Valley Automation & Control Inc.
Renfrew Ontario Canada

© 2011 Pinpoint Laser Systems