Pinpoint Laser Systems
Call 1-800-757-5383  

90-LINE LASER ACCESSORIES

90-Line

What is the 90-Line?

The 90-Line is a Laser Microgage attachment for creating a precise right angle laser reference line. Placing the 90-Line into the laser path allows the laser reference beam to pass through the 90-Line and exit as a precise right angle beam. A manually, rotated nosepiece on the 90-Line allows the user to redirect the exiting laser beam through a full rotation. The 90-Line is a key accessory for checking machinery squareness and also establishing precise parallel reference lines for alignment.

What is the Laser Microgage range with the 90-Line?

A good rule of thumb is to use 100 foot beam path with the Laser Microgage 2D and an 80 foot path with the Laser Microgage 2000. For example, if your 90-Line is placed 60 feet away from the laser a Microgage 2D will let you measure to points out 40 feet out from the 90-Line.

90-Line Square Plane

What is the 90-Line Square Plane?

The 90-Line Square Plane adapts the 90-Line for making square plane measurements along the laser beam path. The 90-Line produces a single right angle laser reference beam. Turning the nosepiece of the 90-Line, through a full turn, redirects this outgoing reference beam to define a plane. The correct positioning of the 90-Line relative to the incoming laser beam insures that this new reference plane is precisely flat. A small positioning mount and a small 2 axis digital receiver couple with the 90-Line to insure that the reference plane is absolutely flat.

90-Line Right Angle

Does the 90-Line Right Angle need to be attached to the Laser?

No. The 90-Line has an internal penta-prism optic that turns the light exactly 90 degrees. The 90-Line can be placed anywhere along the laser beam path and will form a right angle beam. Turning the nosepiece redirects the 90 degree line around a full circle to define a plane that is square to the initial laser beam.

What is the accuracy of the 90-Line Right Angle?

The 90-Line provides a right angle beam that is precise to 0.0006 degrees or 2 arc-seconds. This means that the laser beam exiting from the 90-Line will be square to the input laser beam to within 0.0015 inch at a distance of 10 feet. The repeatability of this actual angle is better than 0.0001 degree or 0.4 arc-seconds.


Industry Aligned

Talk to a Pinpoint
Engineer

After filling out this inquiry form, you can immediately download Pinpoint product and application information.


Pinpoint Laser Systems featured in May 2011 Issue of Photonics Spectra

Photonics Spectra


Our Customers

Our Customers Say

"We actually used it (Cylindrical Laser) for aligning the Power Rollers the turbine rotor sits on during inspections and testing. It went extremely well. Didn’t suffer the delays we encountered last year when the turbine rotor shouldered up on the power roller (cost us about 20 hours). It has already paid for itself. Thanks for your help."

Edward W. Williams
TG/MSR Project Manager
Brunswick Nuclear Plant,
Progress Energy Carolinas

"We purchased the Microgage 2000 and the Lateral Pitch Plate for measuring flatness, parallelism, and other applications. We have been extremely satisfied with the entire process. The quality of the parts we received is of the highest order and the accuracy of the measurements is truly spectacular."

Dr. Joshua R. Williams,
Sr. Scientist
XStream Systems, Inc

"This is just an update for you and a testimony to the great help that your product was in assisting us during our installation and maintenance work and shutdown periods. We installed the wedge blocks with ease and they performed in the very same manner. Great product!"

Jeffery W. Evans
Westinghouse Electric Co, LLC

"We are having great success with this unit (Microgage 2D Universal Kit) in moving my machines this year."

Martin Usher
Apollo Machine

"The sales department was very knowledgeable and the technical department was very thorough. The Microgage 2000 was exactly what we needed. We are extremely happy with the results."

Dr. Joshua R. Williams
Senior Scientist
XStream Systems, Inc.

"One thing that stands out and has been commented on by all who have seen the equipment is its design and build quality. It is a beautifully engineered and built piece of equipment, which is a pleasure to use. Well Done!"

Nenad Sarcevic, Engineer
Airbus UK

"We purchased the Microgage 2000 Universal Kit to align a test apparatus so that the floor of the test tank and the left wall are straight down their respective lengths of 80 feet to 0.0002 inch or better. The floor and left wall also had to be perpendicular to each other

The laser system worked extremely well, proving us and our customer the confidence that the installation when as planned within the tolerances."

Drew Disney
Project Coordinator/Quality Assurance Manager
Hewitt (Brockville) Ltd

"We have been using your equipment regularly to align our scanners for last 4 years with excellent results! After using these we actually wonder how we could align our scanners with out using this tool! These have indeed helped us to improve our sensors measurement accuracy many fold."

Manish Garg
Jasch Industries Ltd.

"We have been very pleased with its (Microgage 2D) performance, as well as Ken Nelson’s advice and help. It is quite likely we will be purchasing other units in the future."

Walt Corey
President
Pickwick Manufacturing Services

“I used the Laser for 6 weeks at the factory in China. It is an awesome tool. I aligned everything on the machine and managed to get the whole machine straight, level and square. I had several fixtures made the worked well for quick setup. My only regret is that I couldn't get them to purchase the upgraded controller. Thanks for everything. You have a quality product that delivers exactly as advertised.”

Todd Fletcher
Valley Automation & Control Inc.
Renfrew Ontario Canada

© 2011 Pinpoint Laser Systems